  2. MRI artifact - Wikipedia

    en.wikipedia.org/wiki/MRI_artifact

    A motion artifact is one of the most common artifacts in MR imaging. [2] Motion can cause either ghost images or diffuse image noise in the phase-encoding direction. The reason for mainly affecting data sampling in the phase-encoding direction is the significant difference in the time of acquisition in the frequency- and phase-encoding ...

  3. Ghosting (medical imaging) - Wikipedia

    en.wikipedia.org/wiki/Ghosting_(Medical_imaging)

    This artifact can be a consequence of environmental factors or the human body (such as blood flow, implants, etc.). Ghosting is a multidimensional artifact that occurs in the MRI in the phase-encoded direction (short axis of the image) after applying the Fourier transform.

  4. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    Example Spin echo: T1 weighted: T1: Measuring spin–lattice relaxation by using a short repetition time (TR) and echo time (TE). Lower signal for more water content, [1] as in edema, tumor, infarction, inflammation, infection, hyperacute or chronic hemorrhage. [2] High signal for fat [1] [2] High signal for paramagnetic substances, such as MRI ...

  5. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to form images of the organs in the body.

  6. Phase contrast magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Phase_Contrast_Magnetic...

    Displacement artifacts (also known as misregistration and oblique flow artifacts) occur when there is a time difference between the phase and frequency encoding. These artifacts are highest when the flow direction is within the slice plane (most prominent in the heart and aorta for biological flows) [10]

  7. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...

  8. Diffusion-weighted magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Diffusion-weighted...

    Diffusion imaging is an MRI method that produces in vivo magnetic resonance images of biological tissues sensitized with the local characteristics of molecular diffusion, generally water (but other moieties can also be investigated using MR spectroscopic approaches). [15]

  9. Artifact (error) - Wikipedia

    en.wikipedia.org/wiki/Artifact_(error)

    In medical imaging, artifacts are misrepresentations of tissue structures produced by imaging techniques such as ultrasound, X-ray, CT scan, and magnetic resonance imaging (MRI). These artifacts may be caused by a variety of phenomena such as the underlying physics of the energy-tissue interaction as between ultrasound and air, susceptibility ...