However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...
Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...
center tap A connection on a transformer which has equal voltage to either end of the transformer winding. ceramic resonator A piezoelectric element used to stabilize the frequency of an oscillator. channel Any communication path between a signal transmitter and a signal receiver, or, a pre-selected operating frequency for a radio system.
Typical multi-tap buck–boost transformer. A buck–boost transformer is a type of transformer used to make adjustments to the voltage applied to alternating current equipment. [1] Buck–boost connections are used in several places such as uninterruptible power supply (UPS) units for computers and in the tanning bed industry.
This file contains additional information, probably added from the digital camera or scanner used to create or digitize it. If the file has been modified from its original state, some details may not fully reflect the modified file.
In switch-mode power supplies, center-tapped transformers are often used, sometimes with single diodes or a dual diode half-bridge [2] to optimize their dynamic electromagnetic behavior at the expense of the extra windings. [3] Phantom power can be supplied to a condenser microphone using center tap transformers. One method, called "direct ...
A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to ...
Tap changer A device in a transformer to change the number of coils used Since the voltage ratio of a transformer is based on the ratio of the number of turns between the primary and secondary coils, changing the number of turns changes the voltage. Transformer: TDS Total dissolved solids. A measure of the impurities contained in cooling water