Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).
The dampness results in vaporization where water vapor is transmitted into the building's interiors. Water vapor may enter the building through supply air ducts in building slabs and circulated by warm forced air. Water vapor can also enter a building through leaky return air ducts in homes with crawlspaces. [4]: 185–187
Interstitial condensation is a type of condensation that may occur within an enclosed wall, roof or floor cavity structure, which can create dampening.. When moisture-laden air at dew point temperature penetrates inside a cavity of the structure, it condenses into liquid water on that surface.
The function of a vapor barrier is to retard the migration of water vapor. A vapor barrier is not typically intended to retard the migration of air. This is the function of air barriers. [8] Air is mixed with water vapor. When air moves from location to location due to an air pressure difference, the vapor moves with it.
Process duct work conveys large volumes of hot, dusty air from processing equipment to mills, baghouses to other process equipment. Process duct work may be round or rectangular. Although round duct work costs more to fabricate than rectangular duct work, it requires fewer stiffeners and is favored in many applications over rectangular ductwork.
Interior of German mechanical fire damper inside of a galvanised steel duct. Fire dampers (or fire shutters) are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent and isolate the spread of fire inside the ductwork through fire-resistance rated walls and floors. [1]
Warm air systems distribute the heated air through ductwork systems of supply and return air through metal or fiberglass ducts. Many systems use the same ducts to distribute air cooled by an evaporator coil for air conditioning. The air supply is normally filtered through air filters [dubious – discuss] to remove dust and pollen particles. [15]
A demister is a substance applied to transparent surfaces to stop them from becoming fogged with mist deposit, often referred to as fog. Scuba divers often spit into their masks and then wash the surface quickly with water to prevent mist buildup that can impair vision. Several products are commercially available such as Sea Drops that are ...