The LVAD is the most common device applied to a defective heart (it is sufficient in most cases; the right side of the heart is then often able to make use of the heavily increased blood flow), but when the pulmonary arterial resistance is high, then an (additional) right ventricular assist device (RVAD) might be necessary to resolve the ...
Ventricular assist devices require open-heart surgery for implantation. An incision is made through the breastbone to expose the heart. Heparin will be given to keep the patients blood from clotting. The blood is rerouted to a heart-lung machine that will pump and oxygenate blood. A pocket for the LVAD is formed in the abdominal wall.
Pump thrombosis (PT) is considered a specific case of a major device malfunction, and is classified as either suspected or confirmed pump thrombus. Typically, the device is an implanted blood pump such as a left ventricular assist device. The malfunction is a blockage in the flow of blood anywhere along a vessel (upstream or downstream) and it ...
The Impella device is an alternative for percutaneous mechanical circulatory support that has been utilized as a bridge to recovery. Used alone or in tandem sets, it utilizes the concept of magnetic levitation [clarification needed] to reduce moving parts to an absolute minimum, thus reducing anticoagulation requirements.
However, there has recently been a move towards the use of the fifth Korotkoff sound (i.e. silence) as the diastolic blood pressure, as this has been felt to be more reproducible. [9] For paediatrics, there has been controversy regarding whether to use auscultation of the fourth or fifth Korotkoff sound as an indicator of diastolic pressure ...
Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.
These are the first heart sound (S 1) and second heart sound (S 2), produced by the closing of the atrioventricular valves and semilunar valves, respectively. In addition to these normal sounds, a variety of other sounds may be present including heart murmurs , adventitious sounds , and gallop rhythms S 3 and S 4 .
More modern devices have software designed to attempt a discrimination between ventricular fibrillation and ventricular tachycardia (VT), and may try to pace the heart faster than its intrinsic rate in the case of VT, to try to break the tachycardia before it progresses to ventricular fibrillation. This is known as overdrive pacing, or anti ...