enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...

  3. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  4. Self-consolidating concrete - Wikipedia

    en.wikipedia.org/wiki/Self-consolidating_concrete

    Self-consolidating concrete or self-compacting concrete (SCC) [1] is a concrete mix which has a low yield stress, high deformability, good segregation resistance (prevents separation of particles in the mix), and moderate viscosity (necessary to ensure uniform suspension of solid particles during transportation, placement (without external compaction), and thereafter until the concrete sets).

  5. Water–cement ratio - Wikipedia

    en.wikipedia.org/wiki/Water–cement_ratio

    However, a fresh concrete with a w/c ratio of 0.35 may not mix thoroughly, and may not flow well enough to be correctly placed and to fill all the voids in the forms, especially in the case of a dense steel reinforcement. More water is therefore used than is chemically and physically necessary to react with cement.

  6. Properties of concrete - Wikipedia

    en.wikipedia.org/wiki/Properties_of_concrete

    The ultimate strength of concrete is influenced by the water-cementitious ratio (w/cm), the design constituents, and the mixing, placement and curing methods employed.All things being equal, concrete with a lower water-cement (cementitious) ratio makes a stronger concrete than that with a higher ratio. [2]

  7. Los Angeles abrasion test - Wikipedia

    en.wikipedia.org/wiki/Los_Angeles_abrasion_test

    The federal standard for LA abrasion testing was formally adopted by the ASTM in 1937. [10] Decades later, field studies found that the LA test results do not always correlate with reality, thus engineers outside of the United States developed different national standards like the French wet micro-Deval procedure or the British Standard 812. [1]

  8. Tremie - Wikipedia

    en.wikipedia.org/wiki/Tremie

    The tremie concrete placement method uses a vertical or nearly vertical pipe, through which concrete is placed by gravity feed below water level. [4]The lower end of the pipe is kept immersed in fresh concrete so that concrete rising from the bottom displaces the water above it, thus limiting washing out of the cement content of the fresh concrete at the exposed upper surface.

  9. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation , the water pressure can be boosted by means of a fire pump .