Search results
Results from the WOW.Com Content Network
These 54 elements are provided in a standardized series of logarithmic steps in the spatial frequency range from 0.250 to 912.3 line pairs per millimeter (lp/mm). The series of elements spans the range of resolution of the unaided eye, down to the diffraction limits of conventional light microscopy .
For common tape measurements, the tape used is a steel tape with coefficient of thermal expansion C equal to 0.000,011,6 units per unit length per degree Celsius change. This means that the tape changes length by 1.16 mm per 10 m tape per 10 °C change from the standard temperature of the tape.
The Kibble balance uses an extra calibration step to cancel the effect of the geometry of the coils, removing the main source of uncertainty. This extra step involves moving the force coil through a known magnetic flux at a known speed.
Properly, the meter calibration constant as well as the ISO speed should be stated, but this seldom is done. Values for the reflected-light calibration constant K vary slightly among manufacturers; a common choice is 12.5 (Canon, Nikon, and Sekonic [8]). Using K = 12.5, the relationship between EV at ISO 100 and luminance L is then
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
To perform a full calibration by the Zhang method, at least three different images of the calibration target/gauge are required, either by moving the gauge or the camera itself. If some of the intrinsic parameters are given as data (orthogonality of the image or optical center coordinates), the number of images required can be reduced to two.
Length measurement, distance measurement, or range measurement (ranging) all refer to the many ways in which length, distance, or range can be measured.The most commonly used approaches are the rulers, followed by transit-time methods and the interferometer methods based upon the speed of light.