Search results
Results from the WOW.Com Content Network
These 54 elements are provided in a standardized series of logarithmic steps in the spatial frequency range from 0.250 to 912.3 line pairs per millimeter (lp/mm). The series of elements spans the range of resolution of the unaided eye, down to the diffraction limits of conventional light microscopy .
Let us now apply Euler's method again with a different step size to generate a second approximation to y(t n+1). We get a second solution, which we label with a (). Take the new step size to be one half of the original step size, and apply two steps of Euler's method. This second solution is presumably more accurate.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Metric gauge block set, 112 pcs Another set with 8 pcs, 125 mm - 500 mm Trolley model. Gauge blocks (also known as gage blocks, Johansson gauges, slip gauges, or Jo blocks) are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific thickness. Gauge ...
To perform a full calibration by the Zhang method, at least three different images of the calibration target/gauge are required, either by moving the gauge or the camera itself. If some of the intrinsic parameters are given as data (orthogonality of the image or optical center coordinates), the number of images required can be reduced to two.
Cutting speed may be defined as the rate at the workpiece surface, irrespective of the machining operation used. A cutting speed for mild steel of 100 ft/min is the same whether it is the speed of the cutter passing over the workpiece, such as in a turning operation, or the speed of the cutter moving past a workpiece, such as in a milling operation.
Ordinary 150 mm (6 in) digital calipers made of stainless steel have a rated accuracy of 0.02 mm and a resolution of 0.01 mm (0.0005 in). [11] The same technology is used for longer calipers, but accuracy declines to 0.03 mm (0.001 in) for 100–200 mm (4–8 in) and 0.04 mm (0.0015 in) for 200–300 mm (8–12 in) measurements.
By considering a small "window" of the signal, these algorithms look for evidence of a step occurring within the window. The window "slides" across the time series, one time step at a time. The evidence for a step is tested by statistical procedures, for example, by use of the two-sample Student's t-test.