Counts per minute (abbreviated to cpm) is a measure of the detection rate of ionization events per minute. Counts are only manifested in the reading of the measuring instrument, and are not an absolute measure of the strength of the source of radiation. Whilst an instrument will display a rate of cpm, it does not have to detect counts for one ...
The counts display is the simplest, and shows the number of ionizing events detected, displayed either as a count rate, such as "counts per minute" or "counts per second", or as a total number of counts over a set time period (an integrated total). The counts readout is normally used when alpha or beta particles are being detected.
The curie (symbol Ci) is a non-SI unit of radioactivity originally defined in 1910. According to a notice in Nature at the time, it was to be named in honour of Pierre Curie , [ 1 ] but was considered at least by some to be in honour of Marie Skłodowska-Curie as well, [ 2 ] and is in later literature considered to be named for both.
The CD V-700 (often written as "CDV-700") is a Geiger counter employing a probe equipped with a Geiger–Müller tube, manufactured by several companies under contract to United States federal civil defense agencies in the 1950s and 1960s. While all models adhere to a similar size, shape, coloring and form-factor, there were substantial ...
They find wide use in situations where a constant high dose rate is being measured as they have a greater operating lifetime than standard Geiger–Müller tubes, which suffer from gas break down and are generally limited to a life of about 10 11 count events. [1] Additionally, the Geiger–Müller tube cannot operate above about 10 4 counts ...
Alpha scintillation probe under calibration. The most commonly used hand-held survey meters are the scintillation counter, which is used in the measurement of alpha, beta and neutron particles; the Geiger counter, widely used for the measurement of alpha, beta and gamma levels; and the ion chamber, which is used for beta, gamma and X-ray measurements.
Count rate measurements are normally associated with the detection of particles, such as alpha particles and beta particles. However, for gamma ray and X-ray dose measurements a unit such as the gray or sievert is normally used. The following table shows ionising radiation quantities in SI and non-SI units.
count of photons n with energy Q p = h c/λ. [nb 2] photon flux: Φ q: count per second: s −1: T −1: photons per unit time, dn/dt with n = photon number. also called photon power: photon intensity: I: count per steradian per second sr −1 ⋅s −1: T −1: dn/dω: photon radiance: L q: count per square metre per steradian per second m − ...