Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...
The fans used to move these gasses are also large, 250 to 4000 horsepower. Therefore, minimizing duct pressure drop by minimizing turbulence at elbows and transitions is of importance. Duct elbow radius is usually 1 1/2 to 2 times the duct size. The side slopes of transitions are typically 10 to 30 degrees.
The use of the flow coefficient offers a standard method of comparing valve capacities and sizing valves for specific applications that is widely accepted by industry. The general definition of the flow coefficient can be expanded into equations modeling the flow of liquids, gases and steam using the discharge coefficient.
There are two means of providing fire-resistance rated ductwork: Inherently fire-resistant, or proprietary factory assembled ducts which are made of sheet metal shells filled with mixtures of rockwool, fiber and silicon dioxide
In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or dusty climates, it is preferable to minimize ventilation with outdoor air to conserve energy, cost, or filtration.
The ductwork airtightness level is the airflow rate through ductwork leakages divided by the ductwork area. It is recommended to test at least 10% and 10 m 2 of the duct surface including all duct types and a variety of sizes and components. The ductwork surface area is estimated according to EN 14239.
The range of Reynold's number that defines each type of flow depends on whether the air is moving through a pipe, wide duct, open channel, or around airfoils. Reynold's number can also characterize an object (for example, a particle under the effect of gravitational settling) moving through a fluid.