  1. Results from the WOW.Com Content Network
  2. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible.A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator.

  3. Supercooling - Wikipedia

    en.wikipedia.org/wiki/Supercooling

    Its glass transition temperature is much colder and harder to determine, but studies estimate it at about 136 K (−137 °C; −215 °F). [9] Glassy water can be heated up to approximately 150 K (−123 °C; −190 °F) without nucleation occurring. [ 8 ]

  4. Subcooling - Wikipedia

    en.wikipedia.org/wiki/Subcooling

    The term subcooling (also called undercooling) refers to the intentional process of cooling a liquid below its normal boiling point. For example, water boils at 373 K; at room temperature (293 K) liquid water is termed "subcooled". Subcooling is a common stage in refrigeration cycles and steam turbine cycles.

  5. Engineering Equation Solver - Wikipedia

    en.wikipedia.org/wiki/Engineering_Equation_Solver

    Engineering Equation Solver (EES) is a commercial software package used for solution of systems of simultaneous non-linear equations.It provides many useful specialized functions and equations for the solution of thermodynamics and heat transfer problems, making it a useful and widely used program for mechanical engineers working in these fields.

  6. Superheated water - Wikipedia

    en.wikipedia.org/wiki/Superheated_water

    This pressure is given by the saturated vapour pressure, and can be looked up in steam tables, or calculated. [9] As a guide, the saturated vapour pressure at 121 °C is 200 kPa, 150 °C is 470 kPa, and 200 °C is 1550 kPa. The critical point is 21.7 MPa at a temperature of 374 °C, above which water is supercritical rather than superheated ...

  7. Flash-gas (refrigeration) - Wikipedia

    en.wikipedia.org/wiki/Flash-gas_(refrigeration)

    The incorporation of a subcooling stage after the receiver reduces even more the chances to observe flash gas. [5] This subcooling may be done in a reserved portion of the main condenser, or separately with a heat exchanger. Some receivers may incorporate an internal heat exchanger that draws heat form the subcooled liquid to superheat the gas ...

  8. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The heat pump itself can be improved by increasing the size of the internal heat exchangers, which in turn increases the efficiency (and the cost) relative to the power of the compressor, and also by reducing the system's internal temperature gap over the compressor. Obviously, this latter measure makes some heat pumps unsuitable to produce ...

  9. Enthalpy–entropy chart - Wikipedia

    en.wikipedia.org/wiki/Enthalpy–entropy_chart

    The diagram was created in 1904, when Richard Mollier plotted the total heat [4] H against entropy S. [5] [1]At the 1923 Thermodynamics Conference held in Los Angeles it was decided to name, in his honor, as a "Mollier diagram" any thermodynamic diagram using the enthalpy as one of its axes.