Amniotic fluid index (AFI) is a quantitative estimate of amniotic fluid [1] and an indicator of fetal well-being. It is a separate measurement from the biophysical profile. [1] AFI is the score (expressed in centimetres) given to the amount of amniotic fluid seen on ultrasonography of a pregnant uterus.
Amniotic fluid is removed from the mother by an amniocentesis procedure, where a long needle is inserted through the abdomen into the amniotic sac, using ultrasound guidance such that the fetus is not harmed. Amniocentesis is a low risk procedure, with risk of pregnancy loss between 1 in 1,500 – 1 in 700 procedures.
Polyhydramnios is a medical condition describing an excess of amniotic fluid in the amniotic sac.It is seen in about 1% of pregnancies. [1] [2] [3] It is typically diagnosed when the amniotic fluid index (AFI) is greater than 24 cm. [4] [5] There are two clinical varieties of polyhydramnios: chronic polyhydramnios where excess amniotic fluid accumulates gradually, and acute polyhydramnios ...
Often referred to as the "water" which surrounds an unborn baby, amniotic fluid plays a vital role in fetal development. Skip to main content. Sign in. Mail. 24/7 Help. For premium support please ...
The volume of amniotic fluid typically increases until 36 weeks and starts decreasing after 40 weeks in post-term gestations. [4] For this reason, discrepancies between fundal height measurements and gestational age can be a clinical indication of amniotic fluid abnormality and should be evaluated by ultrasound.
Several conditions and risk factors can lead to fetal distress or non-reassuring fetal status, [1] including: Low amniotic fluid (oligohydramnios) If there is too little amniotic fluid around the baby in the uterus, the baby can have trouble moving around in the uterus and its growth and temperature can be impacted.
[1] [2] [3] Macrosomia is a similar term that describes excessive birth weight, but refers to an absolute measurement, regardless of gestational age. [4] Typically the threshold for diagnosing macrosomia is a body weight between 4,000 and 4,500 grams (8 lb 13 oz and 9 lb 15 oz), or more, measured at birth, but there are difficulties reaching a ...
This can be done once enough amniotic fluid has developed to sample. Cells from the fetus will be floating in this fluid, and can be separated and tested. Miscarriage risk of amniocentesis is commonly quoted as 0.06% (1:1600). [68] By amniocentesis it is also possible to cryopreserve amniotic stem cells. [69] [70] [71] After 15 weeks More invasive