No specific set of criteria has been developed for diagnosis of pacemaker syndrome. Most of the signs and symptoms of pacemaker syndrome are nonspecific, and many are prevalent in the elderly population at baseline. In the lab, pacemaker interrogation plays a crucial role in determining if the pacemaker mode had any contribution to symptoms. [5 ...
Pacemaker failure is the inability of an implanted artificial pacemaker to perform its intended function of regulating the beating of the heart. A pacemaker uses electrical impulses delivered by electrodes in order to contract the heart muscles. [ 1 ]
Medtronic and Vitatron pacemakers are interrogated and programmed by Medtronic Carelink Model 2090 Programmer for Medtronic and Vitatron Devices; they use separate interfaces. [75] In 2007, Medtronic recalled its Sprint Fidelis product, the flexible wires, or leads, which connect a defibrillator to the interior of the heart.
Twiddler's syndrome is a malfunction of a pacemaker due to manipulation of the device and the consequent dislodging of the leads from their intended location. As the leads move, they stop pacing the heart and can cause strange symptoms such as phrenic nerve stimulation resulting in abdominal pulsing or brachial plexus stimulation resulting in rhythmic arm twitching. [1]
The pacemaker generator is a hermetically sealed device containing a power source, usually a lithium battery, a sensing amplifier which processes the electrical manifestation of naturally occurring heart beats as sensed by the heart electrodes, the computer logic for the pacemaker and the output circuitry which delivers the pacing impulse to ...
In patients with acute signs of heart failure, small percutaneous (introduced to the heart through the skin into a blood vessel rather than through an incision) VADs such as the Impella 5.5, Impella RP, and others can be introduced to either the left or right ventricle (depending on the patient-specific needs) using a wire and that is ...
Pacemaker crosstalk results when the pacemaker-generated electrical event in one heart chamber is sensed by the lead in another chamber, resulting in inappropriate inhibition of the pacing artifact in the second chamber.
The ILR is a useful diagnostic tool to investigate patients who experience symptoms such as syncope (fainting), seizures, recurrent palpitations, lightheadedness, or dizziness not often enough to be captured by a 24-hour or 30-day external monitor. Because of the ILR's long battery life (up to 3 years), the heart can be monitored for an ...