  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Q = Volumetric flow rate of air in cubic feet per minute (cfm) Vol = Space volume L × W × H, in cubic feet; In metric units = where: ACPH = number of air changes per hour; higher values correspond to more ventilation; Q = Volumetric flow rate of air in liters per second (L/s)

  3. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    A basic duct leakage testing system includes three components: a calibrated fan, a register sealing system, and a device to measure fan flow and building pressure. Supply registers or return air grills are sealed using adhesive tapes, cardboard, or non-adhesive reusable seals.

  4. Air flow meter - Wikipedia

    en.wikipedia.org/wiki/Air_flow_meter

    Air flow meters monitor air (compressed, forced, or ambient) in many manufacturing processes. In many industries, preheated air (called "combustion air") is added to boiler fuel just before fuel ignition to ensure the proper ratio of fuel to air for an efficient flame.

  5. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    In reality the fan system efficiency is often in the range 0 to 60% (i.e. <); it is lowest for small fans or inefficient operating points (e.g. throttled flow or free-flow). The efficiency is a function of the total losses in the fan system, including aerodynamic losses in the fan, friction losses in the drive (e.g. belt), losses in the ...

  6. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    Two Water Test Facilities with chambers capable of simulating eight inches (203 mm) of rain-fall per hour and wind speeds of 50 mph (80 km/h). Multi Nozzle Chambers that are capable of measuring airflow up to 88,000 cfm. Circulator Fan Facility capable of testing 96 inch fans. Acoustic Duct Silencer Facility; ISO/IEC 17025 accredited

  7. Energy factor - Wikipedia

    en.wikipedia.org/wiki/Energy_factor

    The energy factor metric only applies to residential water heaters, which are currently defined by fuel, type, and input capacity. [5] Generally, the EF number represents the thermal efficiency of the water heater as a percentage, since it is an average of the ratio of the theoretical heat required to raise the temperature of water drawn to the amount of energy actually consumed by the water ...

  8. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same.

  9. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...