enow.com Web Search

  1. Ad

    related to: bonding jumper vs grounding adapter connector for air compressor

Search results

  1. Results from the WOW.Com Content Network
  2. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    [2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground. This must be ...

  3. Copper tubing - Wikipedia

    en.wikipedia.org/wiki/Copper_tubing

    A similar bonding jumper wire is used between the inlet and outlet of gas meters, but here the purpose is to avoid having a substantial voltage difference between the building’s grounding electrode(s) and buried natural gas lines appear across the gas meter during the brief interval when a line to ground fault is conducting before the ...

  4. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).

  5. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Box connectors join conduit to a junction box or other electrical box. A typical box connector is inserted into a knockout in a junction box, with the threaded end then being secured with a ring (called a lock nut ) from within the box, as a bolt would be secured by a nut.

  6. Electrical bonding - Wikipedia

    en.wikipedia.org/wiki/Electrical_bonding

    Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.

  7. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    Grounding connectors. Connectors for earthing installation are a means of communication between the various components of the earthing and lightning protection installations (earthing rods, earthing conductors, current leads, busbars, etc.). For high voltage installations, exothermic welding is used for underground connections.

  8. U.S. Military connector specifications - Wikipedia

    en.wikipedia.org/wiki/U.S._Military_connector...

    A MIL-DTL-38999 circular connector plated with a nickel–teflon composite. Left: plug (male) type connector; Right: receptacle (female) type connector) Electrical or fiber-optic connectors used by U.S. Department of Defense were originally developed in the 1930s for severe aeronautical and tactical service applications, and the Type "AN" series set the standard for modern military circular ...

  9. Exothermic welding - Wikipedia

    en.wikipedia.org/wiki/Exothermic_welding

    Exothermic welding, also known as exothermic bonding, thermite welding (TW), [1] and thermit welding, [1] is a welding process that employs molten metal to permanently join the conductors. The process employs an exothermic reaction of a thermite composition to heat the metal, and requires no external source of heat or current.

  1. Ad

    related to: bonding jumper vs grounding adapter connector for air compressor