If the electrical axis is between -30° and -90° this is considered left axis deviation. If the electrical axis is between +90° and +180° this is considered right axis deviation (RAD). RAD is an ECG finding that arises either as an anatomically normal variant or an indicator of underlying pathology.
Nonetheless, the ECG is used to assist with the diagnosis of RVH. A post mortem study on 51 adult male patients concluded that anatomical RVH may be diagnosed using one or more of the following ECG criteria: [8] Right axis deviation of more than (or equal to) 110° (see hexaxial reference figure) R-wave dominant over S-wave in V1 or V2
R or S in limb leads ≥20 mm; S in V 1 or V 2 ≥30 mm; R in V 5 or V 6 ≥30 mm; 3 ST-T Abnormalities: ST-T vector opposite to QRS without digitalis; ST-T vector opposite to QRS with digitalis; 3 1 Negative terminal P mode in V 1 1 mm in depth and 0.04 sec in duration (indicates left atrial enlargement) 3 Left axis deviation (QRS of −30 ...
There should be a terminal R wave in lead V 1 (often called "R prime," and denoted by R, rR', rsR', rSR', or qR). There must be a prolonged S wave in leads I and V 6 (sometimes referred to as a "slurred" S wave). The T wave should be deflected opposite the terminal deflection of the QRS complex.
rS pattern (small r, deep S) in the inferior leads II, III, and aVF; Delayed intrinsicoid deflection in lead aVL (> 0.045 s) LAFB cannot be diagnosed when a prior inferior wall myocardial infarction (IMI) is evident on the ECG. IMI can also cause extreme left-axis deviation, but will manifest with Q-waves in the inferior leads II, III, and aVF.
Right Atrial Enlargement (RAE) increases the p wave, representing atrial depolarization, on an ECG to an amplitude > 2.5mm in lead II, an abnormality referred to as p-pulmonale, likely due to weakened right atrial myocardium close to the Sinoatrial (SA) node.
A left posterior fascicular block (LPFB), also known as left posterior hemiblock (LPH), is a condition where the left posterior fascicle, which travels to the inferior and posterior portion of the left ventricle, [1] does not conduct the electrical impulses from the atrioventricular node.
A right bundle branch block typically causes prolongation of the last part of the QRS complex and may shift the heart's electrical axis slightly to the right. The ECG will show a terminal R wave in lead V1 and a slurred S wave in lead I. Left bundle branch block widens the entire QRS, and in most cases shifts the heart's electrical axis to the ...