enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Resolution (mass spectrometry) - Wikipedia

    en.wikipedia.org/wiki/Resolution_(mass_spectrometry)

    IUPAC definition. The IUPAC definition for resolution in mass spectrometry is. Where a larger resolution indicates a better separation of peaks. [1][2] This definition is used in a number of mass spectrometry texts. [3][4][5][6][7][8][9][10][11] This use is also implied by the term "high-resolution mass spectrometry." [12]

  3. Angular resolution - Wikipedia

    en.wikipedia.org/wiki/Angular_resolution

    A calculation using Airy discs as point spread function shows that at Dawes' limit there is a 5% dip between the two maxima, whereas at Rayleigh's criterion there is a 26.3% dip. [3] Modern image processing techniques including deconvolution of the point spread function allow resolution of binaries with even less angular separation.

  4. Spectral resolution - Wikipedia

    en.wikipedia.org/wiki/Spectral_resolution

    Spectral resolution. The spectral resolution of a spectrograph, or, more generally, of a frequency spectrum, is a measure of its ability to resolve features in the electromagnetic spectrum. It is usually denoted by , and is closely related to the resolving power of the spectrograph, defined as where is the smallest difference in wavelengths ...

  5. 1951 USAF resolution test chart - Wikipedia

    en.wikipedia.org/wiki/1951_USAF_resolution_test...

    A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens. It is widely used in optical engineering laboratory work to analyze and ...

  6. Dawes' limit - Wikipedia

    en.wikipedia.org/wiki/Dawes'_limit

    Dawes' limit is a formula to express the maximum resolving power of a microscope or telescope. [1] It is so named after its discoverer, William Rutter Dawes , [2] although it is also credited to Lord Rayleigh. The formula takes different forms depending on the units. This formula agrees with the usual at a wavelength of about 460nm, somewhat ...

  7. Optical resolution - Wikipedia

    en.wikipedia.org/wiki/Optical_resolution

    The group is designated by a group number (-2, -1, 0, 1, 2, etc.) which is the power to which 2 should be raised to obtain the spatial frequency of the first element (e.g., group -2 is 0.25 line pairs per millimeter). Each element is the 6th root of 2 smaller than the preceding element in the group (e.g. element 1 is 2^0, element 2 is 2^(-1/6 ...

  8. Numerical aperture - Wikipedia

    en.wikipedia.org/wiki/Numerical_aperture

    In microscopy, NA is important because it indicates the resolving power of a lens. The size of the finest detail that can be resolved (the resolution) is proportional to ⁠ λ / 2NA ⁠, where λ is the wavelength of the light. A lens with a larger numerical aperture will be able to visualize finer details than a lens with a smaller numerical ...

  9. Van Deemter equation - Wikipedia

    en.wikipedia.org/wiki/Van_Deemter_equation

    The van Deemter equation is a hyperbolic function that predicts that there is an optimum velocity at which there will be the minimum variance per unit column length and, thence, a maximum efficiency. The van Deemter equation was the result of the first application of rate theory to the chromatography elution process.