  2. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must first detect a fault condition. In small mains and low-voltage circuit breakers, this is usually done within the device itself. Typically ...

  3. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Switchgear is a combination of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switches are safe to open under normal load current (some switches are not safe to operate under normal or abnormal conditions), while protective devices are safe to open under fault current.

  4. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  5. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    The disconnector is usually not intended for normal control of the circuit, but only for safety isolation. Unlike load switches and circuit breakers , disconnectors lack a mechanism for suppression of electric arcs which occur when conductors carrying high currents are mechanically interrupted.

  6. Switchgear - Wikipedia

    en.wikipedia.org/wiki/Switchgear

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles. Ratings, design, specifications and details of switchgear are set by a multitude of standards.

  7. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    While most modern circuit breakers will interrupt the fault current in less than 50 ms, the fault current from the generator will take several seconds to interrupt because the field current in the rotor takes this amount of time to discharge. The consequences of a two- or three-phase fault between the generator and the first circuit breaker are ...

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    This circuit breaker in a grounded tank (called a dead tank), could interrupt 41.8 kA under 138 kV (10,000 MV·A) and 37.6 kA under 230 kV (15,000 MV·A). This performance was already significant, but the three chambers per pole and the high-pressure source needed for the blast (1.35 MPa ) was a constraint that had to be avoided in subsequent ...