A typically 25% efficiency standard solar still (not allowing for any recovery of rejected latent heat), as the latent heat of vaporization of water is 2.26 MJ per kilogram, [3] should evaporate 2.4 kg (or liters) of water per m 2 per day in a region with an average daily solar irradiation of 21.6 MJ/m 2 (250 watts/m 2), or 873 liters per year ...
A Med-E-Jet vaccination gun from 1980. A jet injector, also known as a jet gun injector, air gun, or pneumatic injector, is a medical instrument that uses a high-pressure jet of liquid medication to penetrate the skin and deliver medication under the skin without a needle. Jet injectors can be single-dose or multi-dose.
Shaking incubator. The next innovation in incubator technology came in the 1960s, when the CO 2 incubator was introduced to the market. [4] Demand came when doctors realized that they could use CO 2 incubators to identify and study pathogens found in patients' bodily fluids. To do this, a sample was harvested and placed onto a sterile dish and ...
A glass still head, upside down. The rounded part was meant to be fitted on the top of the boiling flask. Black-and-white photo of object at the Wellcome Trust museum. The still head is another ancient type of air-cooled condenser. It consists of a roughly globular vessel with an opening at the bottom, through which the vapor is introduced.
Liebig condenser. The Liebig condenser (/ ˈ l iː b ɪ ɡ /, LEE-big) [1] or straight condenser is a piece of laboratory equipment, specifically a condenser consisting of a straight glass tube surrounded by a water jacket.
In microbiological practices, constant shaking allows liquid-grown cell cultures grown to constantly mix with the air. Some key benefits of shaking water bath are user-friendly operation via keypad, convenient bath drains, adjustable shaking frequencies, bright LED-display, optional lift-up bath cover, power switch integrated in keypad and ...
The standard settings for a hot air oven are: 1.5 to 2 hours at 160 °C (320 °F) 6 to 12 minutes at 190 °C (374 °F)....plus the time required to preheat the chamber before beginning the sterilization cycle. If the door is opened before time, heat escapes and the process becomes incomplete.
It is very important to ensure that all of the trapped air is removed from the autoclave before activation, as trapped air is a very poor medium for achieving sterility. Steam at 134 °C (273 °F) can achieve a desired level of sterility in three minutes, while achieving the same level of sterility in hot air requires two hours at 160 °C (320 ...