enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ankle–brachial pressure index - Wikipedia

    en.wikipedia.org/wiki/Ankle–brachial_pressure...

    A Doppler ultrasound blood flow detector, commonly called Doppler wand or Doppler probe, and a sphygmomanometer (blood pressure cuff) are usually needed. The blood pressure cuff is inflated proximal to the artery in question. Measured by the Doppler wand, the inflation continues until the pulse in the artery ceases.

  3. Doppler ultrasonography - Wikipedia

    en.wikipedia.org/wiki/Doppler_ultrasonography

    Applying spectral Doppler to the renal artery and selected interlobular arteries, peak systolic velocities, resistive index, and acceleration curves can be estimated (Figure 4) (e.g., peak systolic velocity of the renal artery above 180 cm/s is a predictor of renal artery stenosis of more than 60%, and a resistive index, which is a calculated ...

  4. Carotid ultrasonography - Wikipedia

    en.wikipedia.org/wiki/Carotid_ultrasonography

    Carotid ultrasound is a low-cost, noninvasive, and accurate diagnostic imaging modality used to evaluate diseases of the carotid arteries. [2] It is most often used to diagnose carotid artery stenosis, a form of atherosclerosis, and has the capability to assess plaque morphology and characteristics. [1]

  5. Arterial resistivity index - Wikipedia

    en.wikipedia.org/wiki/Arterial_resistivity_index

    The arterial resistivity index (also called as Resistance index, abbreviated as RI), developed by Léandre Pourcelot , is a measure of pulsatile blood flow that reflects the resistance to blood flow caused by microvascular bed distal to the site of measurement. It is primarily used in ultrasound imaging to evaluate arteries and solid organ damage.

  6. Buerger's test - Wikipedia

    en.wikipedia.org/wiki/Buerger's_test

    The vascular angle, which is also called Buerger's angle, is the angle to which the leg has to be raised before it becomes pale, whilst lying down. In a limb with a normal circulation the toes and sole of the foot, stay pink, even when the limb is raised by 90 degrees.

  7. Auscultatory gap - Wikipedia

    en.wikipedia.org/wiki/Auscultatory_gap

    The improper interpretation of this gap may lead to blood pressure monitoring errors, [1] [2] such as an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure. In order to correct for an auscultatory gap, the radial pulse should be monitored by palpation. [3]

  8. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...

  9. E/A ratio - Wikipedia

    en.wikipedia.org/wiki/E/A_ratio

    The E/A ratio is a marker of the function of the left ventricle of the heart. It represents the ratio of peak velocity blood flow from left ventricular relaxation in early diastole (the E wave) to peak velocity flow in late diastole caused by atrial contraction (the A wave). [1]