enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Convergence insufficiency - Wikipedia

    en.wikipedia.org/wiki/Convergence_insufficiency

    In studies that used standardized definitions of convergence insufficiency, investigators have reported a prevalence of 4.26% in school and clinic settings. The standard definition of convergence insufficiency is exophoria greater at near than at distance, a receded near point of convergence, and reduced convergence amplitudes at near. [4]

  4. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. Thus a prism of 1 Δ would produce 1 cm visible displacement at 100 cm, or 1 metre. This can be represented mathematically as: = ⁡ where is the amount of prism correction in prism dioptres, and is the angle of deviation of the light.

  5. Exophoria - Wikipedia

    en.wikipedia.org/wiki/Exophoria

    Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [ 1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [ 2] The axis deviation in exophoria is usually mild compared with that of exotropia .

  6. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range ( PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision ( BSV) in the presence of increasing vergence demands. Motor fusion is largely accounted to ...

  7. Prism (geometry) - Wikipedia

    en.wikipedia.org/wiki/Prism_(geometry)

    Prism (geometry) In geometry, a prism is a polyhedron comprising an n-sided polygon base, a second base which is a translated copy (rigidly moved without rotation) of the first, and n other faces, necessarily all parallelograms, joining corresponding sides of the two bases. All cross-sections parallel to the bases are translations of the bases.

  8. Minimum deviation - Wikipedia

    en.wikipedia.org/wiki/Minimum_deviation

    In minimum deviation, the refracted ray in the prism is parallel to its base. In other words, the light ray is symmetrical about the axis of symmetry of the prism. [1] [2] [3] Also, the angles of refractions are equal i.e. r 1 = r 2. The angle of incidence and angle of emergence equal each other (i = e). This is clearly visible in the graph below.

  9. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).

  1. Related searches base in prism for exophoria 1 cm m and x 2 n 3 n 6 3n 8 simplify

    base in prism for exophoria 1 cm m and x 2 n 3 n 6 3n 8 simplify 5