enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    All NEMA 6 devices are three-wire grounding devices (hot-hot-ground) used for 208 and 240 V circuits and rated for 250 V maximum, with the 6-15, 6-20 and 6-30 being grounding versions of the 2-15, 2-20 and 2-30, respectively. The 6-15 resembles the 5-15, but with collinear horizontal pins, spaced 23 ⁄ 32 in (18.3 mm) center-to-center. The 20 ...

  3. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    Diagram of a possible configuration of ring final circuit. Consumer unit is at bottom left. The ring starts at the consumer unit (also known as fuse box, distribution board, or breaker box), visits each socket in turn, and then returns to the consumer unit. The ring is fed from a fuse or circuit breaker in the consumer unit.

  4. Wiring diagram - Wikipedia

    en.wikipedia.org/wiki/Wiring_diagram

    Architectural style wiring diagram, with lamps and switches shown symbolically in their physical locations on the plan view of the building. Architectural wiring diagrams show the approximate locations and interconnections of receptacles, lighting, and permanent electrical services in a building. Interconnecting wire routes may be shown ...

  5. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    Series II current ratings are 20, 30, 60, 100, 200, 300, 350, 500 and 600 amps. The voltage ratings go up to 1000 V AC. These have been replacing the American-style for some time and are much more likely to be found in food processing, data centers, healthcare, entertainment, and other industries.

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    An outlet is defined by the NEC as "a point in the wiring system at which current is taken to utilization equipment". [1] This definition includes receptacles, lighting, motors, etc. Ordinary switches control but do not consume electricity, and therefore are not defined as outlets in this sense.

  7. AC power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets

    This is the general rating of the adaptor, and indicates the maximum total load in amps, regardless of the number of sockets used (for example, if a 16 A 250 V adaptor has four sockets, it would be fine to plug four different devices into it that each consume 2 A as this represents a total load of only 8 A, whereas if only two devices were ...

  8. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Diagram of a simple electrical cable with three insulated conductors, with IEC colour scheme. About 1950, PVC insulation and jackets were introduced, especially for residential wiring. About the same time, single conductors with a thinner PVC insulation and a thin nylon jacket (e.g. US Type THN, THHN, etc.) became common. [citation needed]

  9. Anderson Powerpole - Wikipedia

    en.wikipedia.org/wiki/Anderson_Powerpole

    This is an accepted version of this page This is the latest accepted revision, reviewed on 4 October 2024. Family of electrical connectors Anderson Powerpole Anderson Powerpole 15/30/45 ampere housings and contacts (front view) Type Electrical connector The Anderson Powerpole is a family of electrical connectors by Anderson Power Products (APP), although plug compatible connectors are now ...