Search results
Results from the WOW.Com Content Network
The allowed cell rate is the rate in cells per second at which a source device may send data in ATM networks. It is bounded by the minimum cell rate and the peak cell rate . [ 1 ]
A chart of accounts (COA) is a list of financial accounts and reference numbers, grouped into categories, such as assets, liabilities, equity, revenue and expenses, and used for recording transactions in the organization's general ledger. Accounts may be associated with an identifier (account number) and a caption or header and are coded by ...
They appear in the Butler–Volmer equation and related expressions. The symmetry factor and the charge transfer coefficient are dimensionless. [1] According to an IUPAC definition, [2] for a reaction with a single rate-determining step, the charge transfer coefficient for a cathodic reaction (the cathodic transfer coefficient, α c) is defined as:
Charge carrier density, also known as carrier concentration, denotes the number of charge carriers per volume. In SI units, it is measured in m −3. As with any density, in principle it can depend on position. However, usually carrier concentration is given as a single number, and represents the average carrier density over the whole material.
In other words, it assumes that the mass transfer rate is much greater than the reaction rate, and that the reaction is dominated by the slower chemical reaction rate. Despite this limitation, the utility of the Butler–Volmer equation in electrochemistry is wide, and it is often considered to be "central in the phenomenological electrode ...
Such rates provide insights into the structure and bonding in the analyte and the electrode. For example, the exchange current densities for platinum and mercury electrodes for reduction of protons differ by a factor of 10 10 , indicative of the excellent catalytic properties of platinum.
This is the energy (i.e. work) per charge which is required to move a (very small) positive charge at constant velocity across the cell membrane from the exterior to the interior. (If the charge is allowed to change velocity, the change of kinetic energy and production of radiation [ 1 ] must be taken into account.)
Double-pulsed chronoamperometry waveform showing integrated region for charge determination.. In electrochemistry, chronoamperometry is an analytical technique in which the electric potential of the working electrode is stepped and the resulting current from faradaic processes occurring at the electrode (caused by the potential step) is monitored as a function of time.