  2. What is the formula for calculating the full load current of ......

    www.answers.com/jobs/What_is_the_formula_for_calculating_the_full_load_current...

    Basically the formula is I = P / V where I = amps, P = power (kV) and V = volts for a single phase 11 kV genset the formula is 11000/400 = 27.5 amps max load. For a 3 PHASE GEN then 11000x0.8/400 ...

  3. Convert kva to full load amps? - Answers

    www.answers.com/electrical-engineering/Convert_kva_to_full_load_amps

    kva means 1000 x voltage x currentSo in order to determine the current we need to know the voltage.AnswerA kilovolt ampere (kV.A, not kva) is a measure of a circuit's apparent power, whereas the ...

  4. What is the full load amps of a 3 phase 415v 14.7kw motor?

    www.answers.com/engineering/What_is_the_full_load_amps_of_a_3_phase_415v_14.7...

    The electrical code states that motor feeders have to be rated at 125% of the motors FLA (full load amps). 17 x 125% = 21 amps. A #10 copper conductor with an insulation factor of 75 or 90 degrees ...

  5. What is the full load current of a 2.2KW motor? - Answers

    www.answers.com/physics/What_is_the_full_load_current_of_a_2.2KW_motor

    In this case, for a 2.2 kW motor, assuming a standard voltage of 230V, the full load current would be approximately 9.57 amps. This answer is: 👍 Helpful ( 0 ) 👎 Not Helpful ( 0 )

  6. What is the difference between a full-load current rated current?

    www.answers.com/physics/What_is_the_difference_between_a_full-load_current...

    Full load amps (FLA) refer to the maximum current a motor draws under full load condition, while running load amps (RLA) refer to the current a motor draws while running under operating conditions ...

  7. What instrument is used to check the full load amps of a ... -...

    www.answers.com/engineering/What_instrument_is_used_to_check_the_full_load...

    The FLA of a 1 HP motor at 240 volts would be W = amps x volts, Amps = Watts/Voltage. 746/240 = 3.1 amps full load. Overload the motor and the amps go higher, motor running at no load amps are ...

  8. What is the difference between rated current full load current?

    www.answers.com/.../What_is_the_difference_between_rated_current_full_load_current

    So a 6 kVA 240 v transformer would have a maximum current rating of 6000/240 or 25 amps. Related questions. ... Full-load current refers to the current drawn by an electric motor when operating at ...

  9. How many amps does a 1 hp electric motor pull under a load?

    www.answers.com/.../How_many_amps_does_a_1_hp_electric_motor_pull_under_a_load

    T430.247 of the NEC shows that a 1 hp motor operating at full load on 115v will draw 16 amps, called Full Load Current (FLC). Conductors supplying this motor are required to be 125% of FLC which ...

  10. What is the full load amps for 2.4 hp motor at 460 volts?

    www.answers.com/electrical-engineering/What_is_the_full_load_amps_for_2.4_hp...

    How many amps does a 1 hp electric motor pull under a load? T430.247 of the NEC shows that a 1 hp motor operating at full load on 115v will draw 16 amps, called Full Load Current (FLC).

  11. What is the full load amperage of a 500 HP motor at 4160 volts?

    www.answers.com/natural-sciences/What_is_the_full_load_amperage_of_a_500_HP...

    The FLA of a 1 HP motor at 240 volts would be W = amps x volts, Amps = Watts/Voltage. 746/240 = 3.1 amps full load. Overload the motor and the amps go higher, motor running at no load amps are ...