Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.
PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.
In North America bird names are used for the code words while animal names are used elsewhere. For instance in North America, Grosbeak is a 322.3 mm 2 (636 kcmil) ACSR conductor with 26/7 Aluminium/Steel stranding whereas Egret is the same total aluminium size (322.3 mm 2, 636 kcmil conductor) but with 30/19 Aluminium/Steel stranding. Although ...
The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal equivalents of the sizes stamped on the back. Oblong plates are similarly notched.
Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire
A standard wire gauge. The British Standard Wire Gauge, often referred to as the Standard Wire Gauge or simply SWG, is a unit used to denote wire gauge (size) as defined by BS 3737:1964, a standard that has since been withdrawn. It is also known as the Imperial Wire Gauge or British Standard Gauge. Although its use has significantly declined ...