  2. Custody transfer - Wikipedia

    en.wikipedia.org/wiki/Custody_transfer

    Current volume of a product stored in a tank can be calculated using a tank capacity table (sometimes called "tank calibration table") and current levels and temperatures of a product in a tank. Tank capacity table stores data about level and appropriate volume in a tank and have a very high impact on overall accuracy of volume calculation ...

  3. Volume correction factor - Wikipedia

    en.wikipedia.org/wiki/Volume_Correction_Factor

    These methods are often more time-consuming than entering the values into a VCF calculator; however, due to the variance in methodology and computation of constants, the tables published by the American Petroleum Institute are preferred when dealing with the purchase and sale of crude oil and residual fuels.

  4. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  5. Evans balance - Wikipedia

    en.wikipedia.org/wiki/Evans_balance

    Calibration involves taking three readings: one with an empty tube R 0, one with a tube filled with the calibration reference material, and one with the tube filled with the sample R s. Some balances feature an auto-tare function that eliminates the need for the R 0 measurement. [11] The first two readings provide a calibration constant (C).

  6. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  7. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2 ) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  8. Standard addition - Wikipedia

    en.wikipedia.org/wiki/Standard_addition

    Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...

  9. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The Gran plot is based on the Nernst equation which can be written as = + ⁡ {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.