TIF is a late complication of a tracheotomy and is associated with prolonged endotracheal intubation, as a result of cuff over inflation or a poorly positioned tracheostomy tube. [1] [4] Over inflation of the cuff causes the tracheostomy tube to erode into the posterior aspect of the innominate artery leading to the formation of a fistula. [2]
A tracheostomy tube may be single or dual lumen, and also cuffed or uncuffed. A dual lumen tracheostomy tube consists of an outer cannula or main shaft, an inner cannula, and an obturator. The obturator is used when inserting the tracheostomy tube to guide the placement of the outer cannula and is removed once the outer cannula is in place.
Intubation granuloma is a benign growth of granulation tissue in the larynx or trachea, which arises from tissue trauma due to endotracheal intubation. [1] This medical condition is described as a common late complication of tracheal intubation, specifically caused by irritation to the mucosal tissue of the airway during insertion or removal of the patient's intubation tube.
Diagram of a tracheostomy tube in the trachea: 1 - Vocal folds 2 - Thyroid cartilage 3 - Cricoid cartilage 4 - Tracheal rings 5 - Balloon cuff. Tracheotomy consists of making an incision on the front of the neck and opening a direct airway through an incision in the trachea.
A tracheotome is a medical instrument used to perform an incision in the trachea with a cutting blade operated by a powered cannula. It is often called a tracheostomy tube because once it enters the stoma in the trachea, a breathing tube is connected to a ventilator and oxygen is provided to the lungs.
In cricothyrotomy, the incision or puncture is made through the cricothyroid membrane in between the thyroid cartilage and the cricoid cartilage Photograph of a tracheostomy tube Surgical methods for airway management rely on making a surgical incision below the glottis in order to achieve direct access to the lower respiratory tract ...
Portex Medical (England and France) produced the first cuff-less plastic 'Ivory' endotracheal tubes. [1] Ivan Magill later added a cuff (these were glued on by hand to make the famous Blue-line tube copied by many other manufacturers). Maeterlinck GmbH developed the disposable endotracheal tube and produced many design variations, adding the ...
Inflation is controlled by a pressure monitor, and the cuffs are inflated to about 200 mmHg. [ citation needed ] Of note, therapies are tailored on an individual basis but beginning regimens tend to include daily one-hour treatments that occur 5 days of the week and last 6–8 weeks with an average overall of 35 hours.