The square is pivoted on the (left side 2x4) and locked into the ⊾ 20° degree index at the red marked line. The SECOND image displays ⊾ X = 70° on the clear protractor that is graduated in 360°, ⊾ X = 20° on the Aluminum angle square. Both red lines ⊾ X are Parallel and thereby congruent.
The complementary angles of the arc tan are used on most angle measuring devices in construction. The tangent of hip, valley, and jack rafters are less than 1.00 in all pitches above 0°. An eighteen pitch has a side cut angle of 29.07° and a two pitch has a side cut angle of 44.56° for jack rafters. This is a variation of 15.5° between pitches.
A combination square is a multi-purpose measuring and marking tool used in metalworking, woodworking, and stonemasonry. It is composed of a rule and one or more interchangeable heads that can be attached to the rule. [1] [2] Other names for the tool include adjustable square, combo square, and sliding square.
A birds-mouth joint in a rafter, set upon a double top plate. Shown are the two cuts of the joint: the seat cut and the heel cut. In light frame construction, a birdsmouth joint or bird's beak cut is a woodworking joint that is generally used to connect a roof rafter to the top plate of a supporting wall. [1]
A miter square or mitre square is a hand tool used in woodworking and metalworking for marking and checking angles other than 90°. Most miter squares are for marking and checking 45° angles and its supplementary angle, 135°. [1] [2] A miter is a bevelled edge – usually 45° – used, for example, for making miter joints for woodworking. [2]
The depth of the bearing seat at the ends of underslung LH- and DLH-Series Joists have been established at 5 inches (130 mm) for chord section number 2 through 17. A bearing seat depth of 7 + 1 ⁄ 2 inches (190 mm) has been established for the DLH Series chord section number 18 through 25. [1]
Building codes in the U.S. specify ventilation rates as a minimum of 1 sq ft (0.093 m 2) of opening per 150 sq ft (14 m 2) (1:150) with a ratio of 1:300 in some conditions. [8] Warm air rises, so ceiling insulation is designed to have a higher r-value and the insulation is often installed between the ceiling joists or rafters.
According to The New York Times, the Army has started to "wikify" certain field manuals, allowing any authorized user to update the manuals. [4] This process, specifically using the MediaWiki arm of the military's professional networking application, milSuite, was recognized by the White House as an Open Government Initiative in 2010.