enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Chlorine - Wikipedia

    en.wikipedia.org/wiki/Chlorine

    Photolysis of individual ClO 2 molecules result in the radicals ClO and ClOO, while at room temperature mostly chlorine, oxygen, and some ClO 3 and Cl 2 O 6 are produced. Cl 2 O 3 is also produced when photolysing the solid at −78 °C: it is a dark

  3. Mass spectrum - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrum

    A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...

  4. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    A mass spectrum is a type of plot of the ion signal as a function of the mass-to-charge ratio. These spectra are used to determine the elemental or isotopic signature of a sample, the masses of particles and of molecules, and to elucidate the chemical identity or structure of molecules and other chemical compounds. Discovery of Neon Isotopes

  5. Mass spectral interpretation - Wikipedia

    en.wikipedia.org/wiki/Mass_spectral_interpretation

    Mass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass ...

  6. Selected-ion flow-tube mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Selected-ion_flow-tube...

    In the selected ion flow tube mass spectrometer, SIFT-MS, ions are generated in a microwave plasma ion source, usually from a mixture of laboratory air and water vapor. . From the formed plasma, a single ionic species is selected using a quadrupole mass filter to act as "precursor ions" (also frequently referred to as primary or reagent ions in SIFT-MS and other processes involving chemical ...

  7. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    One of the main benefits of using chemical ionization is that a mass fragment closely corresponding to the molecular weight of the analyte of interest is produced. [21] In positive chemical ionization (PCI) the reagent gas interacts with the target molecule, most often with a proton exchange. This produces the species in relatively high amounts.

  8. Chemical ionization - Wikipedia

    en.wikipedia.org/wiki/Chemical_ionization

    Chemical ionization in an atmospheric pressure electric discharge is called atmospheric pressure chemical ionization (APCI), which usually uses water as the reagent gas. An APCI source is composed of a liquid chromatography outlet, nebulizing the eluent, a heated vaporizer tube, a corona discharge needle and a pinhole entrance to 10 −3 torr ...

  9. Chlorine-releasing compounds - Wikipedia

    en.wikipedia.org/wiki/Chlorine-releasing_compounds

    The hypochlorite anion and chlorine are in equilibrium in water; the position of the equilibrium is pH dependent and low pH (acidic) favors chlorine, [11] Cl 2 + H 2 O ⇌ 2H + + Cl − + ClO −. A hypochlorite bleach can react violently with hydrogen peroxide and produce oxygen gas: H 2 O 2 (aq) + NaOCl (aq) → NaCl (aq) + H 2 O(l) + O 2 (g)