In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.
The first fire extinguisher patent was issued to Alanson Crane of Virginia on Feb. 10, 1863. [12] The first fire sprinkler system was patented by H.W. Pratt in 1872. But the first practical automatic sprinkler system was invented in 1874 by Henry S. Parmalee of New Haven, CT. He installed the system in a piano factory he owned.
Automatic sprinkler System of pipes serving fire sprinklers, for automatically directing water to a fire when the sprinkler is heated to its actuation temperature (usually 155 deg F). The piping may be normally pressurized with water ("wet") or with air ("dry"), depending upon the application.
The fire suppression piping may contain water, air (in a dry system), antifreeze, gas or chemicals as in a hood system, or a mixture producing fire retardant foam. Sprinkler fitters work with a variety of pipe and tubing materials including several types of plastic, copper, steel, cast iron, and ductile iron. [3]
This is typically done with a 1-inch-diameter (25 mm) hose and a fixed nozzle. Therefore, if a water stream breaks over at 50 ft (15 m), then it is said the pump has 50 feet (15 m) of head pressure. Current measurements of pumping capacity are now in GPM, Gallons Per Minute.