Search results
Results from the WOW.Com Content Network
The table below shows computed reinforcement ratios for 10 stress tensors. The applied reinforcement yield stress is = 500 N/mm². The mass density of the reinforcing bars is 7800 kg/m 3. In the table is the computed brittle material stress.
Reinforcing rebar is placed axially in the column to provide additional axial stiffness. Accounting for the additional stiffness of the steel, the nominal loading capacity P n for the column in terms of the maximum compressive stress of the concrete f c ' , the yield stress of the steel f y , the gross cross section area of the column A g , and ...
The table below lists units supported by {{convert}}. More complete lists are linked for each dimension. For a complete list of all dimensions, see full list of units. {{Convert}} uses unit-codes, which are similar to, but not necessarily exactly the same as, the usual written abbreviation for a given unit. These unit-codes are displayed in ...
Within the trades rebar is known by a shorthand utilizing the bar diameter as descriptor, such as "four-bar" for bar that is four-eighths (or one-half) of an inch. The cross-sectional area of a bar, as given by πr ², works out to (bar size/9.027)², which is approximated as (bar size/9)² square inches.
Plastic reinforcement often is stronger, or at least has a better strength to weight ratio than reinforcing steels. Also, because it resists corrosion, it does not need a protective concrete cover as thick as steel reinforcement does (typically 30 to 50 mm or more). FRP-reinforced structures therefore can be lighter and last longer.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
Mass; system unit unit-code symbol or abbrev. notes sample default conversion combinations SI: kilogram: kg kg 1.0 kg (2.2 lb) kg lb. kg lb st; kg st. kg st lb; gram: g g
The required concrete cover depends on several factors, including the environmental conditions to which the structure will be exposed, the size of the reinforcing steel, the concrete strength, and the type of structure being constructed. Generally, larger diameter reinforcement bars require more concrete cover than smaller ones.