In photometry, luminous intensity is a measure of the wavelength-weighted power emitted by a light source in a particular direction per unit solid angle, based on the luminosity function, a standardized model of the sensitivity of the human eye. The SI unit of luminous intensity is the candela (cd), an SI base unit.
The lumen is defined as amount of light given into one steradian by a point source of one candela strength; while the candela, a base SI unit, is defined as the luminous intensity of a source of monochromatic radiation, of frequency 540 terahertz, and a radiant intensity of 1/683 watts per steradian.
Mathematically, for the spectral power distribution of a radiant exitance or irradiance one may write: =where M(λ) is the spectral irradiance (or exitance) of the light (SI units: W/m 2 = kg·m −1 ·s −3); Φ is the radiant flux of the source (SI unit: watt, W); A is the area over which the radiant flux is integrated (SI unit: square meter, m 2); and λ is the wavelength (SI unit: meter, m).
In photometry, luminous flux or luminous power [citation needed] is the measure of the perceived power of light. It differs from radiant flux , the measure of the total power of electromagnetic radiation (including infrared , ultraviolet , and visible light), in that luminous flux is adjusted to reflect the varying sensitivity of the human eye ...
Luminous energy: Q v [nb 3] lumen second: lm⋅s T⋅J: The lumen second is sometimes called the talbot. Luminous flux, luminous power Φ v [nb 3] lumen (= candela steradian) lm (= cd⋅sr) J: Luminous energy per unit time Luminous intensity: I v: candela (= lumen per steradian) cd (= lm/sr) J: Luminous flux per unit solid angle: Luminance: L v ...
Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.
Illuminance diagram with units and terminology. In photometry, illuminance is the total luminous flux incident on a surface, per unit area. [1] It is a measure of how much the incident light illuminates the surface, wavelength-weighted by the luminosity function to correlate with human brightness perception. [2]
Luminous flux per unit solid angle per unit projected source area. The candela per square metre is sometimes called the nit. Illuminance: E v: lux (= lumen per square metre) lx (= lm/m 2) L −2 ⋅J: Luminous flux incident on a surface Luminous exitance, luminous emittance M v: lumen per square metre lm/m 2: L −2 ⋅J: Luminous flux emitted ...