For end-bearing piles, drilling continues until the borehole has extended a sufficient depth (socketing) into a sufficiently strong layer. Depending on site geology, this can be a rock layer, or hardpan, or other dense, strong layers. Both the diameter of the pile and the depth of the pile are highly specific to the ground conditions, loading ...
Unit end bearing resistance and unit skin friction resistance versus SPT N values are given in the FDOT research bulletin RB-121, for the different soil types. Driven pile capacity calculated using CPT data can be determined by three separate methods.
Anchor piles are typically designed to resist both horizontal and vertical loads. The axial holding capacity of the anchor pile is due to the friction along the pile-soil interface, while the lateral capacity of the pile is generated by lateral soil resistance, where the anchor's orientation is critical to optimising this resistance.
Shallow foundations of a house versus the deep foundations of a skyscraper. Foundation with pipe fixtures coming through the sleeves. In engineering, a foundation is the element of a structure which connects it to the ground or more rarely, water (as with floating structures), transferring loads from the structure to the ground.
Franki piles can be used as high-capacity deep foundation elements without the necessity of excavation or dewatering. [4] They are useful in conditions where a sufficient bearing soil can only be reached deeper in the ground, [5] [6] and are best suited to granular soil where bearing is primarily achieved from the densification of the soil around the base. [4]
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
The bearing capacity of soil is the maximum average contact pressure between the foundation and the soil which should not produce shear failure in the soil. Ultimate bearing capacity is the theoretical maximum pressure which can be supported without failure; allowable bearing capacity is the ultimate bearing capacity divided by a factor of ...
Screw piles are typically manufactured from high-strength steel [1] using varying sizes of tubular hollow sections with helical flights. The pile shaft transfers a structure's load into the pile. Helical steel plates are welded to the pile shaft to suit the site specific ground conditions. Helices can be press-formed to a specified pitch or ...