enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    Junctions between fire-resistance-rated wall or floor assemblies; Head-of-wall (HOW) joints, where non-load-bearing wall assemblies meet floor assemblies; Numeric characters are used to identify what penetrant, if any, can be found within the present system and help identify what UL-tested system was used.

  3. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.

  4. Penetration (firestop) - Wikipedia

    en.wikipedia.org/wiki/Penetration_(firestop)

    A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.

  5. Penetrant (mechanical, electrical, or structural) - Wikipedia

    en.wikipedia.org/wiki/Penetrant_(mechanical...

    Penetrants, or penetrating items, are the mechanical, electrical or structural items that pass through an opening in a wall or floor, such as pipes, electrical conduits, ducting, electrical cables and cable trays, or structural steel beams and columns. When these items pierce a wall or floor assembly, they create a space between the penetrant ...

  6. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    Time/temperature curves used for testing the fire-resistance rating of passive fire protection systems such as firestops, fire doors, wall and floor assemblies, etc., which are used in compartmentalisation in buildings and the petrochemical industry in Europe and North America.

  7. Joint (building) - Wikipedia

    en.wikipedia.org/wiki/Joint_(building)

    Where vertical fire-resistance rated wall assemblies meet the underside of the floor slab above, a movement joint results, which can be subject to compression, as the freshly placed concrete cures and shrinks all over a new building. This joint must be firestopped in a flexible manner.

  8. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    A typical test objective for fire rated assemblies is to maintain the item or the side to be protected at or below either 140 °C (for walls, floors and electrical circuits required to have a fire-resistance rating). A typical test objective (e.g., ASTM E119) for fire rated structural protection is to limit the temperature of the structural ...

  9. Building code - Wikipedia

    en.wikipedia.org/wiki/Building_code

    The hole should be firestopped to restore the fire-resistance rating of the wall. Instead, it is filled with flammable polyurethane foam . A building code (also building control or building regulations ) is a set of rules that specify the standards for construction objects such as buildings and non-building structures .