  2. Harmonics (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Harmonics_(electrical_power)

    In power systems, harmonics are defined as positive integer multiples of the fundamental frequency. Thus, the third harmonic is the third multiple of the fundamental frequency. Harmonics in power systems are generated by non-linear loads. Semiconductor devices like transistors, IGBTs, MOSFETs, diodes, etc. are all non-linear loads. Further ...

  3. Ferroresonance in electricity networks - Wikipedia

    en.wikipedia.org/wiki/Ferroresonance_in...

    The phenomenon can be avoided by connecting a minimal resistive load on the transformer secondaries or by interrupting the applied voltage by a 3-phase interrupting device such as a ganged (3-pole) circuit breaker. [8] In many cases, it also suffices to unground the transformer in a Δ configuration, which increases the line shunt impedance.

  4. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Removing harmonics: Dy connection – D winding nullifies 3rd harmonics, preventing it to be reflected on Wye side. Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral.

  5. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  6. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    It is used as a grounding transformer, creating a missing neutral connection from an ungrounded 3-phase system to permit the grounding of that neutral to an earth reference point; to perform harmonic mitigation, as they can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents; [2] to supply 3-phase power as an autotransformer ...

  7. Voltage optimisation - Wikipedia

    en.wikipedia.org/wiki/Voltage_optimisation

    The possible effects if the level of harmonics, known as total harmonic distortion becomes too high include damage to sensitive electronic equipment [5] and reduction in the efficiency of the HV transformer. [6] The efficiency of electrical loads can be improved by attenuating harmonics at the supply, or by preventing their generation.

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Transformer oil is flammable, so oil-filled transformers inside a building are installed in vaults to prevent spread of fire and smoke from a burning transformer. Some transformers were built to use fire-resistant PCBs , but because these compounds persist in the environment and have adverse effects on organisms, their use has been discontinued ...

  9. HVDC converter - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter

    HVDC systems based on voltage-source converters normally use the six-pulse connection because the converter produces much less harmonic distortion than a comparable LCC and the twelve-pulse connection is unnecessary. This simplifies the construction of the converter transformer.