enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Deep foundation - Wikipedia

    en.wikipedia.org/wiki/Deep_foundation

    For end-bearing piles, drilling continues until the borehole has extended a sufficient depth (socketing) into a sufficiently strong layer. Depending on site geology, this can be a rock layer, or hardpan, or other dense, strong layers. Both the diameter of the pile and the depth of the pile are highly specific to the ground conditions, loading ...

  3. Wave equation analysis - Wikipedia

    en.wikipedia.org/wiki/Wave_equation_analysis

    The soil response for each pile segment is modeled as viscoelastic-plastic. The method was first developed in the 1950s by E.A. Smith of the Raymond Pile Driving Company. Wave equation analysis of piles has seen many improvements since the 1950s such as including a thermodynamic diesel hammer model and residual stress. Commercial software ...

  4. Danish pile-driving formula - Wikipedia

    en.wikipedia.org/wiki/Danish_pile-driving_formula

    Q dy = ultimate dynamic bearing capacity of driven pile; α = pile driving hammer efficiency; W H = weight of hammer; H = hammer drop; S = inelastic set of piles, in distance pr. hammer blow; S e = elastic set of piles, in distance pr. hammer blow; L = pile length; A = pile end area; E = modulus of elasticity of pile material

  5. Bearing capacity - Wikipedia

    en.wikipedia.org/wiki/Bearing_capacity

    The bearing capacity of soil is the maximum average contact pressure between the foundation and the soil which should not produce shear failure in the soil. Ultimate bearing capacity is the theoretical maximum pressure which can be supported without failure; allowable bearing capacity is the ultimate bearing capacity divided by a factor of ...

  6. Dynamic load testing - Wikipedia

    en.wikipedia.org/wiki/Dynamic_load_testing

    Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...

  7. Franki piling system - Wikipedia

    en.wikipedia.org/wiki/Franki_Piling_System

    Franki piles can be used as high-capacity deep foundation elements without the necessity of excavation or dewatering. [4] They are useful in conditions where a sufficient bearing soil can only be reached deeper in the ground, [5] [6] and are best suited to granular soil where bearing is primarily achieved from the densification of the soil around the base. [4]

  8. Static load testing - Wikipedia

    en.wikipedia.org/wiki/Static_load_testing

    Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.

  9. Statnamic load test - Wikipedia

    en.wikipedia.org/wiki/Statnamic_load_test

    The Statnamic load test is a type of test for assessing the load-carrying capacity of deep foundations which is faster and less expensive than the static load test.The Statnamic test was conceived in 1985, with the first prototype tests carried out in 1988 through collaboration between Berminghammer Foundation Equipment of Canada and TNO Building Research of the Netherlands.