Search results
Results from the WOW.Com Content Network
Fire blocking or firestopping terminology was used interchangeably in code language from its first mention in the 1905 National Building Code (NBC), and requirements were expanded in the 1927 Uniform Building Code (UBC). Building code terminology settled on different definitions of the terms by 2000. [4]
A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.
Building codes require a firestop to seal the openings around penetrants. Electrical cable through-penetration, fire-stopped by an intumescent sealant, to restore the two-hour fire-resistance rating of the concrete floor.
[1] [2] The compilation organizes the general Acts of Illinois into 67 chapters arranged within 9 major topic areas. [3] The ILCS took effect in 1993, replacing the previous numbering scheme generally known as the Illinois Revised Statutes (Ill. Rev. Stat.), the latest of which had been adopted in 1874 but appended by private publishers since. [3]
Depiction of New York World Building fire in New York City in 1882. Building codes in the United States are a collection of regulations and laws adopted by state and local jurisdictions that set “minimum requirements for how structural systems, plumbing, heating, ventilation, and air conditioning (), natural gas systems and other aspects of residential and commercial buildings should be ...
Requirements for earthquake (seismic code), hurricane, flood, and tsunami resistance, especially in disaster prone areas or for very large buildings where a failure would be catastrophic [citation needed] Requirements for specific building uses (for example, storage of flammable substances, or housing a large number of people)
A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.
Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. [1] [2] It involves the study of the behaviour, compartmentalisation, suppression and investigation of fire and its related emergencies, as well as the research and development, production, testing and application of mitigating systems.