Ads
related to: interior perimeter drainage system costtemu.com has been visited by 1M+ users in the past month
Search results
Results from the WOW.Com Content Network
Many interior drainage systems are patented and recognized by Building Officials and Code Administrators(BOCA) as being effective in controlling basement water. A common system for draining water that has penetrated a basement involves creating a channel around the perimeter of the basement alongside the foundation footers.
A French drain[1] (also known by other names including trench drain, blind drain, [1] rubble drain, [1] and rock drain[1]) is a trench filled with gravel or rock, or both, with or without a perforated pipe that redirects surface water and groundwater away from an area. The perforated pipe is called a weeping tile (also called a drain tile or ...
While these curtain wall systems are more energy-efficient than older, single-glazed versions, they are still significantly less efficient than opaque (solid) wall construction. [13] For example, nearly all curtain wall systems, thermally-broken or otherwise, have a U-value of 0.2 or higher, which is equivalent to an R-value of 5 or lower. [14]
The infill wall is the supported wall that closes the perimeter of a building constructed with a three-dimensional framework structure (generally made of steel or reinforced concrete). Therefore, the structural frame ensures the bearing function, whereas the infill wall serves to separate inner and outer space, filling up the boxes of the outer ...
In civil engineering, the invert level is the base interior level of a pipe, trench or tunnel; it can be considered the "floor" level. [1] The invert is an important datum for determining the functioning or flowline of a piping system. For example, the invert of a street sewer connection could affect the feasibility of adding a toilet in the ...
Flashing refers to thin pieces of impervious material installed to prevent the passage of water into a structure from a joint or as part of a weather resistant barrier system. In modern buildings, flashing is intended to decrease water penetration at objects such as chimneys , vent pipes, walls, windows and door openings to make buildings more ...
Drainage. High-density polyethylene pipe installation in a storm drain project, Mexico. Drainage is the natural or artificial removal of a surface's water and sub-surface water from an area with excess water. The internal drainage of most agricultural soils can prevent severe waterlogging (anaerobic conditions that harm root growth), but many ...
Exterior insulation and finish system (EIFS) is a general class of non- load bearing building cladding systems that provides exterior walls with an insulated, water-resistant, finished surface in an integrated composite material system. EIFS has been in use since the 1960s in North America and was first used on masonry buildings.
Ads
related to: interior perimeter drainage system costtemu.com has been visited by 1M+ users in the past month