Search results
Results from the WOW.Com Content Network
A size chart illustrating the ANSI sizes. In 1992, the American National Standards Institute adopted ANSI/ASME Y14.1 Decimal Inch Drawing Sheet Size and Format, [1] which defined a regular series of paper sizes based upon the de facto standard 8 + 1 ⁄ 2 in × 11 in "letter" size to which it assigned the designation "ANSI A".
In plumbing, a trap is a U-shaped portion of pipe designed to trap liquid or gas to prevent unwanted flow; most notably sewer gases from entering buildings while allowing waste materials to pass through. In oil refineries, traps are used to prevent hydrocarbons and other dangerous gases and chemical fumes from escaping through drains.
ISO Lettering templates, designed for use with technical pens and pencils, and to suit ISO paper sizes, produce lettering characters to an international standard. The stroke thickness is related to the character height (for example, 2.5 mm high characters would have a stroke thickness - pen nib size - of 0.25 mm, 3.5 would use a 0.35 mm pen and ...
MasterFormat is a standard for organizing specifications and other written information for commercial and institutional building projects in the U.S. and Canada. [1] Sometimes referred to as the "Dewey Decimal System" of building construction, MasterFormat is a product of the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC).
An architectural drawing or architect's drawing is a technical drawing of a building (or building project) that falls within the definition of architecture.Architectural drawings are used by architects and others for a number of purposes: to develop a design idea into a coherent proposal, to communicate ideas and concepts, to convince clients of the merits of a design, to assist a building ...
Grease trap for greywater in Lima, Peru. A grease trap (also known as grease interceptor, grease recovery device, grease capsule and grease converter) is a plumbing device (a type of trap) designed to intercept most greases and solids before they enter a wastewater disposal system.
Usually, each floor drain is connected to a trap, to prevent sewer gases from escaping into indoors spaces. A floor sink is a type of floor drain primarily used as an indirect waste receptor. It is generally deeper than a standard floor drain and can have a full or partial grate, or no grate as required to accommodate the indirect waste pipes.
A standard widely use in the United States is: A112.1.2 Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-Connected Receptors) In the United Kingdom, legislation is by statutory instrument and varies by country, but includes Water Supply (Water Quality) Regulations 2016 and Water Supply (Water Quality) Regulations (Wales).