enow.com Web Search

  1. Ad

    related to: platelet function assay levels

Search results

  1. Results from the WOW.Com Content Network
  2. PFA-100 - Wikipedia

    en.wikipedia.org/wiki/PFA-100

    The PFA test result is dependent on platelet function, plasma von Willebrand Factor level, platelet number, and (to some extent) the hematocrit (that is, the percent composition of red blood cells in the sample). The PFA test is initially performed with the Collagen/Epinepherine membrane.

  3. Platelet - Wikipedia

    en.wikipedia.org/wiki/Platelet

    The PFA-100 (Platelet Function Assay — 100) is a system for analysing platelet function in which citrated whole blood is aspirated through a disposable cartridge containing an aperture within a membrane coated with either collagen and epinephrine or collagen and ADP. These agonists induce platelet adhesion, activation and aggregation, leading ...

  4. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    Still, the blood values are approximately equal between the arterial and venous sides for most substances, with the exception of acid–base, blood gases and drugs (used in therapeutic drug monitoring (TDM) assays). [6] Arterial levels for drugs are generally higher than venous levels because of extraction while passing through tissues. [6]

  5. Ristocetin-induced platelet aggregation - Wikipedia

    en.wikipedia.org/wiki/Ristocetin-induced...

    It is similar to the ristocetin cofactor assay but has the added benefit in that it helps in the diagnosis of type 2B/pseudo von Willebrand disease (vWD) and Bernard–Soulier syndrome because it uses patient's live endogenous platelets, whereas ristocetin cofactor assay tests the function of only the vWF and not the platelets. Ristocetin ...

  6. Bleeding time - Wikipedia

    en.wikipedia.org/wiki/Bleeding_time

    Bleeding time is a medical test done to assess the function of a person's platelets. It involves making a patient bleed, then timing how long it takes for them to stop bleeding using a stopwatch or other suitable devices. The term template bleeding time is used when the test is performed to standardized parameters.

  7. Thromboelastography - Wikipedia

    en.wikipedia.org/wiki/Thromboelastography

    Aspirin inhibits platelet function via the AA pathway while clopidogrel inhibits platelet function via the ADP pathway; thus, this test can be used to determine the degree to which a patient is anticoagulated due to either medication. In this assay, a standard TEG is run using patient's whole blood.

  8. Thromboelastometry - Wikipedia

    en.wikipedia.org/wiki/Thromboelastometry

    It reflects the absolute strength of the fibrin and platelet clot. A low MCF is indicative of decreased platelet number or function, decreased fibrinogen level or fibrin polymerization disorders, or low activity of factor XIII. A mechanically weak clot represents a severe bleeding risk and should initiate immediate therapeutic steps.

  9. Multiple electrode aggregometry - Wikipedia

    en.wikipedia.org/wiki/Multiple_electrode...

    Multiplate multiple electrode aggregometry (MEA) is a test of platelet function in whole blood. [1] [2] The test can be used to diagnose platelet disorders, [3] [4] [5] monitor antiplatelet therapy, [6] and is also investigated as a potential predictor of transfusion requirements and bleeding risk in cardiac surgery. [7]