A sphygmomanometer (/ ˌ s f ɪ ɡ m oʊ m ə ˈ n ɒ m ɪ t ə r / SFIG-moh-mə-NO-mi-tər), also known as a blood pressure monitor, or blood pressure gauge, is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, [1] and a mercury or aneroid manometer to measure the pressure.
When the heart ejects stroke volume to the arteries, it takes a certain transit time until the blood pressure wave arrives in the periphery. This pulse transit time (PTT) indirectly depends on blood pressure – the higher the pressure, the faster PTT. This circumstance can be used for the noninvasive detection of blood pressure changes.
A minimum systolic value can be roughly estimated by palpation, most often used in emergency situations, but should be used with caution. [10] It has been estimated that, using 50% percentiles, carotid, femoral and radial pulses are present in patients with a systolic blood pressure > 70 mmHg, carotid and femoral pulses alone in patients with systolic blood pressure of > 50 mmHg, and only a ...
Blood-related parameters are listed in a blood test. Electrocardiograph records the electrical activity of the heart; Glucose meter for obtaining the status of blood sugar. Sphygmomanometer, a blood pressure meter used to determine blood pressure in medicine. See also Category:Blood tests
Ambulatory blood pressure monitoring allows blood pressure to be intermittently monitored during sleep and is useful to determine whether the patient is a "dipper" or "non-dipper"—that is to say, whether or not blood pressure falls at night compared to daytime values. A nighttime fall is normal and desirable.
Systems for monitoring the gases being administered to, and exhaled by, the patient, including an oxygen failure warning device; Systems for monitoring the patient's heart rate, ECG, blood pressure and oxygen saturation may be incorporated, in some cases with additional options for monitoring end-tidal carbon dioxide and temperature. [2]
A pulse oximeter probe applied to a person's finger. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood (as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in the skin, producing a photoplethysmogram that may be further processed into other measurements. [4]
An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well.