Additional requirements and requirements for structures in consequence class 1 can be found in the material specific Eurocode parts, EN 1992 for concrete structures, EN 1993 for steel structures and so on. In EN 1991-1-7 buildings are categorised in consequences classes, considering the building type, occupancy and size. [1]
Concrete has numerous applications in building construction, but its use for horizontal slabs is limited by its relatively high density which reduces the maximum span. [2] The usual method of rectifying this disadvantage is to incorporate some kind of reinforcement, which enables concrete slabs to be used for a broad range of spans and loading ...
Cubic or cylindrical samples of concrete are tested under a compression testing machine to measure this value. Test requirements vary by country based on their differing design codes. Use of a Compressometer is common. As per Indian codes, compressive strength of concrete is defined as: Field cured concrete in cubic steel molds (Greece)
It must allow the architecture to work, and the building services to fit within the building and function (air conditioning, ventilation, smoke extract, electrics, lighting, etc.). The structural design of a modern building can be extremely complex and often requires a large team to complete. Structural engineering specialties for buildings ...
Prestressed concrete is a method for overcoming the concrete's natural weakness in tension. [ 1 ] [ 2 ] It can be used to produce beams , floors or bridges with a longer span than is practical with ordinary reinforced concrete .
In the building and construction industry, until 25–30 years old, prescriptive codes, regulations and standards made innovation and change difficult and costly to implement, and created technical restrictions to trade. These concerns have been the major drivers towards the use of a Performance Based approach to codes, regulations and standards.
The ACI Building Code Requirements put the following restrictions on amount of spiral reinforcement. ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in.
Concrete has a very low coefficient of thermal expansion, and as it matures concrete shrinks. All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1]