enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    For air flow at room temperature, when the outlet pressure is less than 1/2 the absolute inlet pressure, the flow becomes quite simple (although it reaches sonic velocity internally). With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm).

  5. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .

  6. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    The cause for this is the separation of the flow from the blade surfaces. This effect can be explained by the flow over an air foil. When the angle of incidence increases (during the low velocity flow) at the entrance of the air foil, flow pattern changes and separation occurs. This is the first stage of stalling and through this separation ...

  7. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  8. Airflow - Wikipedia

    en.wikipedia.org/wiki/Airflow

    Like any fluid, air may exhibit both laminar and turbulent flow patterns. Laminar flow occurs when air can flow smoothly, and exhibits a parabolic velocity profile; turbulent flow occurs when there is an irregularity (such as a disruption in the surface across which the fluid is flowing), which alters the direction of movement.

  9. Airwatt - Wikipedia

    en.wikipedia.org/wiki/Airwatt

    An alternative airwattage formula is from ASTM International (see document ASTM F558 - 13) [4] P = 0.117354 ⋅ F ⋅ S {\displaystyle P=0.117354\cdot F\cdot S} Where P is the power in airwatts, F is the rate per minute (denoted cu ft/min or CFM) and S is the suction capacity expressed as a pressure in inches of water.