enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Sail switch - Wikipedia

    en.wikipedia.org/wiki/Sail_switch

    A sail switch, vane switch or flow switch is a mechanical switch that is actuated on or off in response to the flow or non-flow of a fluid such as air or water. [1] A sail switch typically operates through the use of a paddle or a diaphragm which gets displaced due to the force of fluid or air moving past it.

  3. Pilot light - Wikipedia

    en.wikipedia.org/wiki/Pilot_light

    In natural gas furnaces, water heaters, and room heating systems, a safety cut-off switch is normally included so that the gas supply to the pilot and heating system is shut off by an electrically operated valve if the pilot light goes out. This cut-off switch usually detects the pilot light in one of several ways: A flame rectification device. [2]

  4. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    An 80 US gal (300 L; 67 imp gal) electric storage tank water heater was able to have a minimum energy factor of 86% under the pre-2015 standard, while under the 2015 standard, the minimum energy factor for an 80-gallon electric storage tank water heater is now 197%, which is only possible with heat pump technology. This rating measures ...

  5. Reversing valve - Wikipedia

    en.wikipedia.org/wiki/Reversing_valve

    Reversing valves are built into the heat pump by the manufacturer, and must be replaced by an HVAC technician if they fail. Since the valve is an integral part of the sealed refrigerant circuit, proper procedures for recovering and then later refilling the refrigerant must be followed, to prevent its loss into the atmosphere.

  6. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    A district heating system uses centrally located boilers or water heaters and circulates heat energy to individual customers by circulating hot water or steam. This has the advantage of a central highly efficient energy converter that can use the best available pollution controls, and that is professionally operated.

  7. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.

  8. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]

  9. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    The program features include time schedules, set points, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/cold water and/or steam ...