This image is of the angle of the eye as seen through a slit lamp. It is labelled as Grade 4 according to Van Herick's Grading system. The Van Herick's technique compares the depth of the peripheral anterior chamber with the cornea thickness, usually written as a fraction [6] however, it can also be expressed as a ratio (see table 3). [5]
A slit lamp exam allows a detailed inspection of the conjunctiva and sclera and improves the detection of globe injury. Slit lamp exam findings like decreased anterior chamber depth or damage to posterior chamber structures indicate open-globe injury. [3] A seidel test detects more subtle or partially self-sealing open-globe injuries.
Determining the anterior chamber depth (ACD) is important in estimating the risk of angle closure glaucoma. There are various methods of measuring ACD, including examination through a slit lamp , ultrasound and Scheimpflug photography.
Eye examination with the aid of a slit lamp. Side view of a slit lamp machine. Cataract in human eye: magnified view seen on examination with the slit lamp. In ophthalmology and optometry, a slit lamp is an instrument consisting of a high-intensity light source that can be focused to shine a thin sheet of light into the eye.
In ophthalmology, gonioscopy is a routine procedure that measures the angle between the iris and the cornea (the iridocorneal angle), using a goniolens (also known as a gonioscope) together with a slit lamp or operating microscope. [1] [2] Its use is important in diagnosing and monitoring various eye conditions associated with glaucoma.
Shallow anterior chamber depth may indicate a predisposition to one form of glaucoma (narrow angle) but requires slit-lamp examination or other special techniques to determine it. In the presence of a "red eye", a shallow anterior chamber may indicate acute glaucoma, which requires immediate attention.
OCT Biomicroscopy is the use of optical coherence tomography (OCT) in place of slit lamp biomicroscopy to examine the transparent axial tissues of the eye. [1] Traditionally, ophthalmic biomicroscopy has been completed with a slit lamp biomicroscope that uses slit beam illumination and an optical microscope to enable stereoscopic, magnified, cross-sectional views of transparent tissues in the ...
Anterior chamber: fluid-filled space between the iris and the endothelium: AC 4/4: Grade 4 anterior chamber angle: open angle between cornea and iris AC 3/4: Grade 3 anterior chamber angle: AC 2/4: Grade 2 anterior chamber angle: AC 1/4: Grade 1 anterior chamber angle: AC 0/4: Grade 0 anterior chamber angle: closed angle between cornea and iris ...