Search results
Results from the WOW.Com Content Network
The energy conserving property has been defined as thermal emittance (the ability of a surface to release radiant energy that it has absorbed). Those coatings qualified as Interior Radiation Control Coatings must show a thermal emittance of 0.25 or less. This means that an IRCCS will block 75% or more of the radiant heat transfer. These low "E ...
Radiant heating as a technology is more narrowly defined. It is the method of intentionally using the principles of radiant heat to transfer radiant energy from an emitting heat source to an object. Designs with radiant heating are seen as replacements for conventional convection heating as well as a way of supplying confined outdoor heating.
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...
PDRC surfaces are designed to be high in solar reflectance to minimize heat gain and strong in longwave infrared (LWIR) thermal radiation heat transfer matching the atmosphere's infrared window (8–13 μm). [23] [2] [3] This allows the heat to pass through the atmosphere into space. [6] [24]
Convective heat transfer with underfloor systems is much greater when the system is operating in a heating rather than cooling mode. [60] Typically with underfloor heating the convective component is almost 50% of the total heat transfer and in underfloor cooling the convective component is less than 10%. [61]
A radiant barrier reduces the radiant heat transfer from the underside of the roof to the other surfaces in the attic. Some studies show that radiant barriers can reduce cooling costs 5% to 10% when used in a warm, sunny climate. The reduced heat gain may even allow for a smaller air conditioning system.
Central heating systems: These systems produce heat in one central location and distribute it throughout the building. This category includes furnaces, boilers, and heat pumps. [1] [2] Distributed heating systems: These systems generate heat in the space they are to heat, without extensive duct systems. Examples include electric space heaters ...