In civil engineering, concrete leveling is a procedure that attempts to correct an uneven concrete surface by altering the foundation that the surface sits upon. It is a cheaper alternative to having replacement concrete poured and is commonly performed at small businesses and private homes as well as at factories, warehouses, airports and on roads, highways and other infrastructure.
The overall mass of concrete can be reduced by 35–50% depending on the design, [1] as a consequence of reduced slab mass, as well as lower requirements for vertical structure and foundations. Biaxial slabs commonly span up to 20 metres at a thickness of around 500 mm. [ citation needed ] The added strength also reduces the acoustic ...
By John Riha A stamped concrete patio gives you the look and texture of a stone patio for a lot less than the real thing -- up to 50 percent less than the cost of natural slate or limestone. That ...
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
Papercrete is a new material that serves as a good substitute for concrete. Papercrete is shredded paper, sand, and cement mixed together to form a very durable brick-like material. Buildings utilizing papercrete are well-insulated and resistant to termites and fire. Papercrete is very cheap as it usually only costs about $0.35 per square foot.
Tilt-up, tilt-slab or tilt-wall is a type of building and a construction technique using concrete. Though it is a cost-effective technique with a shorter completion time, [ 1 ] poor performance in earthquakes has mandated significant seismic retrofit requirements in older buildings.
The precast concrete slab has tubular voids extending the full length of the slab, typically with a diameter equal to the 2/3–3/4 the thickness of the slab. This makes the slab much lighter than a massive solid concrete floor slab of equal thickness or strength. The reduced weight also lowers material and transportation costs.
The slab can be decoupled from ground temperatures by insulation, with the concrete poured directly over insulation (for example, extruded polystyrene foam panels), or heating provisions (such as hydronic heating) can be built into the slab. Slab-on-grade foundations should not be used in areas with expansive clay soil.