Search results
Results from the WOW.Com Content Network
If the condensate from the cooling coils is drained away from the room as it drips off the cooling coils, the result will be room air that is drier but slightly warmer. However, many window air conditioners are designed to dispose of condensate water by re-evaporating it into the exhaust air stream, which cancels out the air humidity decrease ...
This stage may switch off the HVAC equipment (preventing the production of further condensate), trigger an alarm, or both. Some systems may include two pumps to empty the tank. In this case, the two pumps often alternate operation, and a two-stage switch serves to energize the on-duty pump at the first stage and then energize the remaining pump ...
The control circuit in a household HVAC installation. The wires connecting to the blue terminal block on the upper-right of the board lead to the thermostat. The fan enclosure is directly behind the board, and the filters can be seen at the top. The safety interlock switch is at the bottom left. In the lower middle is the capacitor.
Assembly drawings detail how certain component parts are assembled. [2] An assembly drawing shows which order the product is put together, showing all the parts as if they were stretched out. This will help a welder to understand how the product will go together so he get an idea of where the weld is needed.
A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy. Generally, it refers ...
At the bottom of the shell, where the condensate collects, an outlet is installed. In some designs, a sump (often referred to as the hotwell) is provided. Condensate is pumped from the outlet or the hotwell for reuse as boiler feedwater. For most water-cooled surface condensers, the shell is under [partial] vacuum during normal operating ...
Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.
A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible.A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator.