An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.
Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.
A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3]
An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high-voltage source and voltage and current meters. A single instrument called a "pressure test set" or "hipot tester" is often used to perform this test.
The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]
Basic insulation is any material added to protect a user from accidental contact with energized parts. Supplemental insulation is rated to withstand 1500 volts AC. Double insulation is a design concept where failure of one insulation system will not expose the user to a shock hazard due to the presence of a second independent layer of insulation.
Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.
An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth. It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 k Ω (sample of IEC standard for medical applications).