  2. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits Black: 6 or 8 AWG wire (13.3 mm 2 or 8.37 mm 2) for 60- and 45-amp circuits, respectively Grey: usage for underground installations, designated as "underground feeder" (UF) cables [4] The outer jacket is labeled with letters that show how ...

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  6. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    Today, porcelain standoffs are still commonly used with bare-wire electric fencing for livestock, and such porcelain standoffs carry far higher voltage surges without risk of shorting to ground. In summary, K&T wiring that was installed correctly, and not damaged or incorrectly modified since then, is fairly safe when used within the original ...

  7. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    In the late 1960s problems and failures related to branch circuit connections for building wire made with the utility grade AA-1350 alloy aluminum began to surface, resulting in a re-evaluation of the use of that alloy for building wire and an identification of the need for newer alloys to produce aluminum building wire. The first 8000 series ...