enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Breaking capacity or interrupting rating [1] [2] is the current that a fuse, circuit breaker, or other electrical apparatus is able to interrupt without being destroyed or causing an electric arc with unacceptable duration.

  3. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    In particular, the stress on the switching path caused by current and voltage during switching on and off is of enormous importance. For example, the switch-on and switch-off current at resistance load corresponds to the continuous operating current, while, for example, squirrel cage motors consumes multiple of the rated operating current ...

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines rated current as the maximum current that a breaker is designed to carry continuously. The commonly available preferred values for rated current are 1 A, 2 A, 4 A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A, [ 6 ] and 125 A.

  5. NEMA contact ratings - Wikipedia

    en.wikipedia.org/wiki/NEMA_contact_ratings

    NEMA contact ratings are how much current at a rated voltage a relay or other pilot device can switch. The current rating of smaller NEMA contactors or their auxiliaries are defined by NEMA ICS 5: Industrial Control and Systems, Control Circuit and Pilot Devices [1] standard. The nomenclature is a letter followed by a three-digit number, the ...

  6. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    The maximum voltage rating of IEC 60309 connectors is 1000 V DC or AC; the maximum current rating is 800 A; and the maximum frequency 500 Hz. Plugs are available in P+N+E (unbalanced single phase with neutral), 2P+E (balanced single phase), 3P+E (3 phase without neutral), and 3P+N+E (three phase with neutral).

  7. Renard series - Wikipedia

    en.wikipedia.org/wiki/Renard_series

    One application of the Renard series of numbers is the current rating of electric fuses. Another common use is the voltage rating of capacitors (e.g. 100 V, 160 V, 250 V, 400 V, 630 V). Comparison of preferred numbers of the 1-2-5, Renard and f-stop series on a logarithmic scale divided into 40 equal intervals (blue)

  8. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A single insulated conductor in free air has 70 A rating. Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor.

  9. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power outlet can rise relative to the local earth (concrete floor, water pipe etc.) to a ...